
This menu allows the user to manage the gatefold covers through the new voice at the menu :
Enter Administration > Parameters / Gatefold Covers
1) This feature allows you to set granularity publication with one or more templates with Gatefold covers.
2) With button you can create a new Gatefold cover
3) Fill in the form with:
Field | Description |
---|---|
Name* | cover identifier, univocal at header level (eg 6 pages with inverted leaf) |
Cover pages* | total number of cover pages (greater than or equal to 6) |
Cover fold* | * |
Encoding string* | text coding of the graphic representation in the plan drawing |
Icon | ** Image with three-dimensional representation of the cover to which the template refers |
* Required Field
(*) Present to guarantee the functioning of all the algorithms that make use of this data; it continues to be enhanced with the current rules, ie it represents the number of cover pages prior to the fold (position of the internal leaflet) looking at the outer expanse of the covers
(**) Images must be JPEG / PNG with a maximum size of 600x300 px
4) Batch upload
There is also the possibility of template's batch loading with publication granularity, through the ZIP import function. The ZIP file must contain a CSV file with the comma as a field separator and double quotes as text delimiters, and at the same level all the images of the templates to be loaded. The CSV consists of 5 fields to be specified in the first line: cover_name, cover_pages, cover_fold, cover_encoding, cover_img
5) Import file ZIP
Before importing the ZIP file it is possible to decide whether or not to delete the data already present, by selecting or deselecting the box Delete old data.
Construction Rules of the string encoding of the graphical representation in the plan design
The string consists of the following special characters:
"@" (At): is the page separator and is used to divide the attributes of a page from those on the next page
"R" (Right): is a page attribute that establishes that the page is right
"L" (Left): is a page attribute that establishes that the page is left
"^" (Caret): represents the position indicator of the internal foliation and indicates the attachment point of the same; consequently the pages that are found before this separator in the encoding string are considered to be prior to the Roman, while those that are found later are considered subsequent to the last of foliation. Also acts as a page separator, therefore you should not put the "@" character between the two pages separated by "^"
"," (Comma) is the separator attributes and is used to divide the attributes of a page
Plan Module
In the Plan module, when creating the number, you need to choose the cover type. The choice and configuration of the Normal cover remains unchanged, while the choice of the Gatefold Cover type is available only if at least one template is defined at publication level. In the latter case the cover template can be chosen by clicking on the Choose ... button, scrolling through the images with the three-dimensional representations of the same and by double-clicking on the chosen record: when confirming the number, all the configurations associated with it will be automatically applied.
The design of the Gatefold covers consists of a single line on which the pages are represented in the order specified by the string encoding, and varies depending on the value assigned to the configuration of the publication COVER_placement VIEW group.
Example: 6 pages with fold on cover II (internal leaf)
With this configuration the encoding string and the plan display change according to the left / right property assigned to the II cover.
The corresponding three-dimensional model is illustrated by the following images:
II cover as right page
The editorial view in the plan with a COVER_placement configuration set to NO is as follows:
The editorial view in the plan with COVER_placement configuration set to YES is as follows:
II cover as left page
In this case, the II of the cover and the Roman II constitute a couple on which it is possible to place a double page advertisement.
The editorial view in the plan with a COVER_placement configuration set to NO is as follows:
The editorial view in the plan with COVER_placement configuration set to YES is as follows:
6 pages with fold inverted (external Gatefold)
With this configuration, the plan display is unique. The corresponding three-dimensional model is illustrated by the following images:
The editorial view in the plan with a COVER_placement configuration set to NO is as follows:
The editorial view in the plan with COVER_placement configuration set to YES is as follows:
Image visualisation plan with the three-dimensional representation of Gatefold cover
In the plan, if present a Gatefold cover, an icon is visible with which it is possible to recall by double-clicking the visualisation of the image with the three-dimensional representation of the covers, so as to facilitate users in understanding the layout of the pages . The image can also be called up from the menu item Views> Show Gatefold cover.
Plan view of pages smaller than the standard format issue.
Some pages belonging to the gatefold cover may be smaller than the standard format assigned to the issue. The grid of these pages is designed respecting the real dimensions of the assigned page format, both in the plan and in the preview window; the difference in size in the plan is highlighted by a profile with a transparent background designed respecting the standard format issue
Multi-edition view with Gatefolder
In the multi-edition view, the Gatefold covers are designed respecting the order specified in the encoding string.
Edit a Gatefold Cover
The user can edit a gatefold cover details by clicking
Perform your changes and confirm with or cancel with
.
Remove a Gatefold Cover
The user can remove a gatefold cover by clicking .